5017 Kétcsatornás, nyomon követhető időzítő

MŰSZAKI ADATOK
- Timing Capacity: 99 hours, 59 minutes, 59 seconds
- Timing Accuracy: £0.01%
- Timing Channels: 2 independent timing channels
- Countdown Memory: 1 per channel
- Alarm Volume: High, Low, or Mute
VISUAL LED ALERT
For each channel, during countdown timing, the LED around the corresponding T1 / T2 button will flash green every 4 seconds when time remaining is greater than 60 seconds, every 2 seconds when time remaining is less than 60 seconds, but greater than 10 seconds, and every second when time remaining is less than 10 seconds. During countdown timing, when the display reaches zero for a channel, the LED around the corresponding T1 / T2 button will flash red for up to sixty (60) seconds, or until the S/S button is pressed. The visual LED alert is not affected by the alarm volume.
RIASZTÁSI HANGERŐ
Slide the alarm volume switch, located on the right side of the timer, to the desired position. HI (high alarm volume), LO (low alarm volume) or MUTE (no alarm audible sound). The alarm volume may be changed at any time without affecting the timing operation. The visual LED alert is not affected by the alarm volume.
A KIJELZŐ TÖRLÉSE NULLÁRA
Select the desired channel by pressing the T1 / T2 button. Press the HR and MIN buttons simultaneously to clear the display to zero. To clear the display to zero when time is running on the selected channel, stop the timing by pressing the S/S button, then press the HR and MIN buttons simultaneously. The timer will only clear when time is stopped for the selected channel.
VISSZASZÁMLÁLÓ ÉBRESZTÉS IDŐZÍTÉSE
- Select the desired channel by pressing the T1 / T2button.
- Clear the display to zero.
- Press the HR (hours), MIN (minutes) and SEC (seconds) buttons to advance the display to the desired countdown time.
- Once the desired time is on the display, press the S/S button to begin countdown timing.
- When the timing channel reaches zero, the alarm will start (audible and visual or visual only, depending on the alarm volume setting), and the timing channel will begin counting up.
- Az ébresztő egy percig szól, majd automatikusan kikapcsol az elem élettartamának megőrzése érdekében, miközben az időzítő csatorna folyamatosan számol.
While a channel is alarming, once the channel is selected by pressing the T1 / T2 button, pressing the S/S button will stop the alarm, stop the count-up timing, and recall the last programmed countdown time. After one minute, pressing the S/S button for the selected channel will stop the count-up timing. Both timing channels may be used simultaneously.
SETTING COUNTDOWN MEMORY
For timing repetitive intervals, the countdown memory function allows up to two (2) distinct countdown times (one per timing channel) to be set into memory and recalled with the press of a button.
- Select the desired channel by pressing the T1 / T2 button.
- Clear the display to zero.
- Press and hold the M (memory) button for three (3) seconds (the display will flash zero).
- Press the HR (hours), MIN (minutes) and SEC (seconds) buttons to advance the display to the desired countdown time.
- With the desired countdown time on the display, press the M (memory) button to confirm the entry (the display will no longer flash).
COUNTDOWN MEMORY TIMING
- Select the desired channel by pressing the T1 / T2 button.
- Clear the display to zero.
- Press the M (memory) button to recall the countdown memory time for the selected channel.
- Press the S/S button to begin countdown timing.
- When the timing channel reaches zero, the alarm will start (audible and visual or visual only, depending on the alarm volume setting), and the timing channel will begin counting up.
Az ébresztő egy percig szól, majd automatikusan kikapcsol az elem élettartamának megőrzése érdekében, miközben az időzítő csatorna folyamatosan számol.
While a channel is alarming, once the channel is selected by pressing the T1 / T2 button, pressing the S/S button will stop the alarm, stop the count-up timing, and recall the programmed countdown time. After one minute, pressing the S/S button for the selected channel will stop the count-up timing. To recall the programmed time, press the M button. Both timing channels may be used simultaneously.
CLEARING COUNTDOWN MEMORY
- Select the desired channel by pressing the T1 / T2 button.
- Clear the display to zero.
- Press and hold the M (memory) button for three (3) seconds (the display will flash zero).
- With the display flashing zero, press the M (memory) button to confirm the entry (the display will no longer flash).
STOPPER (ELŐRESZÁMLÁLÓ) IDŐMÉRÉS
- Select the desired channel by pressing the T1 / T2button.
- Clear the display to zero.
- Press the S/S button to begin count-up timing.
- Press the S/S button to stop count-up timing.
Once timing is complete and the timer has been stopped, press the HR and MIN buttons simultaneously to clear the display to zero. Both timing channels may be used simultaneously for countdown or count-up timing.
IDŐTÚL
A timing channel may be stopped during any running time (countdown or count-up) by selecting the channel and pressing the S/S button. Timing may be resumed by pressing the S/S button a second time.
CONVERT A TIMEOUT TO A COUNTDOWN TIME
A timing channel may be stopped during any running time (countdown or count-up) by selecting the channel and pressing the S/S button. Once the timing has been stopped, pressing the HR, MIN and SEC buttons will increment the display from the point that it was stopped and will set the timer into countdown mode. Once the desired time is on the display, press the S/S button to begin countdown timing.
MINDEN MŰKÖDÉSI NEHÉZSÉG
If this timer does not function properly for any reason, replace the batteries with new high-quality batteries (see the “Battery Replacement” section). Low battery power can occasionally cause any number of “apparent” operational difficulties. Replacing the batteries with new, fresh batteries will solve most difficulties.
AKKUMULÁTORCSERE
An incorrect display, no display or operational difficulties indicate that the batteries should be replaced. Slide open the battery cover on the back of the timer. Insert two (2) new AAA alkaline batteries. Make certain to note the proper polarity as indicated by the diagram in the battery compartment. Replace the battery cover.
GARANCIA, SZOLGÁLTATÁS VAGY KALIBRÁLÁS
- Garanciával, szervizzel vagy kalibrálással kapcsolatban:
TRACEABLE® TERMÉKEK 12554 Old Galveston Rd. B230 lakosztály Webster, Texas 77598 USA - Telefonszám: 281 482-1714 • Fax: 281 482-9448
- E-mail támogatás
- Traceable® Products are ISO 9001:2015 Quality-Certified by DNV and ISO/EC 17025:2017 accredited as a Calibration Laboratory by ALA.
A 5017. katalógusszámú Traceable® a Cole-Parmer bejegyzett védjegye.
©2020 Traceable® termékek. 92-5017-00 Rev. 5 092524
GYIK
K: Hogyan állíthatom le az ébresztőt visszaszámlálás közben?
A: Select the channel and press the S/S button to stop the alarm and recall the last programmed countdown time.
K: Használható mindkét időzítő csatorna egyszerre?
A: Yes, both channels can be used at the same time for independent timing operations.
K: Hogyan óvhatom meg az akkumulátor élettartamát, amikor nincs szükség az ébresztőre?
A: The alarm will automatically turn off after one minute to save battery while the timer continues counting up.
Dokumentumok / Források
![]() |
Traceable 5017 kétcsatornás, nyomon követhető időzítő [pdfUtasítások 5017 kétcsatornás nyomon követhető időzítő, 5017, kétcsatornás nyomon követhető időzítő, csatornánként nyomon követhető időzítő, nyomon követhető időzítő, időzítő |