Lightcloud logóLCGATEWAY/OFC
Telepítési útmutató
Office Gateway Manual

LCGATEWAY-OFC irodai átjáró

Welcome to lighting control that just works.
Lightcloud is a wireless, cloud-based lighting control system that’s incredibly easy to install. There’s no networking or complicated dip switches. Just wire the devices for power and let us know what was installed.

Tartalom

  • Office Gateway
  • Tápkábel
  • Tartószerkezet
  • X2 rögzítőcsavarok
  • Device ID Labels
  • Kézikönyv
  • Panel matrica

Lightcloud LCGATEWAY OFC Office Gateway  - Box

Az eszköz specifikációi

CIKKSZÁM: LCGATEWAY/OFC
ÜZEMI HŐMÉRSÉKLET: 0-40°C
MAXIMUM RELATIVE HUMIDITY: 95%
STORAGE AND TRANSPORTATION TEMPERATURE: -20ºC és 40ºC között
MÉRETEK: 4.97" X 4.97" X 1.5"
AC TÁP BEMENET: Only use with provided power cord.
I NPUT VOLTAGE: 120 VAC, 50/60 HZ
ÁRAMFOGYASZTÁS: 60 mA @ 120V
Egyedi gyártás Kínában
Copyright © 2025 RAB Lighting, Inc.

Lightcloud LCGATEWAY OFC Office Gateway  - Icon

Rendszer végeview

Lightcloud is a wireless, networked lighting control system that enables near limitless control over lighting. Lightcloud can be accessed from nearly anywhere and any device by logging in to control.lightcloud.com.
Lightcloud comes with 10 years of unlimited support, so feel free to contact us if you have any questions at 1 (844) LIGHTCLOUD.

Of fice Gateway

The Lightcloud Of fice Gateway serves two main functions:

  1. On-Site Coordination of Devices. The Office Gateway acts as an on-site brain for up to 200 Lightcloud® devices.
  2. Off-Site Coordination with Lightcloud.
    The Office Gateway communicates with the Lightcloud® cloud for complete control of your system from anywhere.
    An unlimited number of Gateways can be used for wireless control of any size Site.

Telepítés

  1. ELSŐ LÉPÉS
    Helyezze el az átjárót
    a. Avoid problem materials and devices.
    The Gateway needs to be able to communicate wirelessly with other Lightcloud Devices. Don’t place the
    Gateway in a metal enclosure, thick concrete or brick rooms. Also, don’t place the Gateway near microwaves, elevator rooms, amplifiers, or other antennas.
    PROBLEM MATERIALSLightcloud LCGATEWAY OFC Office Gateway  - Icon 1PROBLEM DEVICES & SIGNALS
    Lightcloud LCGATEWAY OFC Office Gateway  - Icon 2 MIKROHULLÁMOK
    Lightcloud LCGATEWAY OFC Office Gateway  - Icon 3 ELEVATOR MECHANICAL ROOMS
    Lightcloud LCGATEWAY OFC Office Gateway  - Icon 4 AMPLIFIERS & ANTENNAS

    b. Choose a location that is as close to as many other Lightcloud devices as possible.Lightcloud LCGATEWAY OFC Office Gateway  - Lightcloud*All of the devices don’t have to be within a 100’ of the Gateway, but its ideal to have as many within direct range as possible.

  2. MÁSODIK LÉPÉS
    Record the Gateway’s Device ID Each Lightcloud device has a unique Device ID for identification that needs to be documented. To document the Device IDs, use one of the following 3 methods.
    a. LC Installer App – Free Scan Device IDs and send information to RAB Download: lightcloud.com/lcinstaller (Elérhető iOS-re és Androidra)Lightcloud LCGATEWAY OFC Office Gateway  - Lightcloud 1b. Device Table – Included with the Gateway
    Attach Device ID stickers to Device Table and complete information.
    Send detailed photos of completed device table to support@lightcloud.com
    Additional Device Tables can be downloaded at lightcloud.com/devicetableLightcloud LCGATEWAY OFC Office Gateway  - Lightcloud 2c. Floor Plan
    Attach the Device Identification sticker to its location on a floor plan, lighting design, or design schedule. Send detailed photos of completed plans to support@lightcloud.com.Lightcloud LCGATEWAY OFC Office Gateway  -Floor Plan
  3. HARMADIK LÉPÉS
    Telepítse az átjárót
    a. Place Gateway on a surface or mount Gateway to wall using bracket and 2 supplied screws.
    b. If using ethernet, plug in ethernet cable.
    c. Plug in power cable.
    d. Verify system statusLightcloud LCGATEWAY OFC Office Gateway  - GatewayOnce all LEDs are solid white, you should be able to connect to your Gateway from control.lightcloud.com or the Lightcloud® Mobile App.
    To check ZigBee (Device Mesh) signal strength, press the recessed device button once. A number of LEDs will turn blue indicating how strong the signal is, from 1 to 4, counting from the bottom up.
    LED állapot Jelentése
    All LEDs solid white Normálisan fut
    All LEDs pulsing white Indítás
    Some LEDs solid blue ZigBee signal strength
    All LEDs solid red Kritikus kudarc
    All LEDs pulsing red Nincs kapcsolat
    All LEDs pulsing green Gateway is in join mode
  4. NEGYEDIK LÉPÉS
    Install and Document Other Lightcloud® Devices a. Follow the Device Manuals to wire the other devices for permanent, unswitched power.
    b. As you wire each device, document their Device IDs using the same method you chose to document the Gateway’s Device ID in step 3.
  5. ÖTÖDIK LÉPÉS
    Submit Device Information After wiring and organizing all the devices, submit the device information using the LC Installer App or email photos of the documented device IDs to support@lightcloud.com.
  6. HATODIK LÉPÉS
    Végeztél!
    Lightcloud Support will remotely configure the system.

FCC információk:

Ez az eszköz megfelel az FCC-szabályok 15. részének. A működés az alábbi két feltételhez kötött:
1. Ez az eszköz nem okozhat káros interferenciát, és 2. Ennek az eszköznek el kell viselnie minden interferenciát, beleértve a nem kívánt működést okozó interferenciát is.
Jegyzet: Ezt az eszközt tesztelték, és megállapították, hogy megfelel a B osztályú digitális eszközökre vonatkozó határértékeknek az FCC-szabályok 15. része B. alrésze szerint. Ezeket a határértékeket úgy alakították ki, hogy ésszerű védelmet nyújtsanak a káros interferencia ellen lakossági környezetben. Ez a berendezés rádiófrekvenciás energiát állít elő, használ és sugározhat ki, és ha nem a használati utasításnak megfelelően telepítik és használják, káros interferenciát okozhat a rádiókommunikációban. Nincs azonban garancia arra, hogy egy adott telepítés során nem lép fel interferencia. Ha ez a berendezés káros interferenciát okoz a rádió- vagy televízióvételben, ami a berendezés ki- és bekapcsolásával állapítható meg, a felhasználót arra ösztönzik, hogy próbálja meg kijavítani az interferenciát az alábbi intézkedések közül egy vagy több segítségével:
– Állítsa át vagy helyezze át a vevőantennát.
– Növelje a távolságot a berendezés és a vevő között.
– Csatlakoztassa a berendezést a vevőegységtől eltérő áramkörön lévő aljzathoz.
– Kérjen segítséget a kereskedőtől vagy egy tapasztalt rádió-/TV-szerelőtől.
To comply with the FCC’s RF exposure limits for general population / uncontrolled exposure, this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in
bármely más antennával vagy adóval együtt.
VIGYÁZAT: A berendezésen a RAB Lighting által kifejezetten nem jóváhagyott változtatások vagy módosítások érvényteleníthetik a felhasználó jogosultságát a berendezés üzemeltetésére.

Lightcloud Logo 1

Dokumentumok / Források

Lightcloud LCGATEWAY-OFC Office Gateway [pdfTelepítési útmutató
LCGATEWAY-OFC, LCGATEWAY-OFC Office Gateway, Office Gateway, Gateway

Hivatkozások

Hagyj megjegyzést

E-mail címét nem tesszük közzé. A kötelező mezők meg vannak jelölve *