COMMSCOPE CPP-UDDM-SL-1U-24 árnyékolatlan diszkrét elosztómodul
Műszaki adatok
- Anyagazonosító: 760237040
- Cikkszám: CPP-UDDM-SL-1U-24
- Leírás: Árnyékolatlan diszkrét elosztómodul panel, SL, 1U, 24 port, fekete
Általános
The CommScope® Unshielded discrete distribution module (UDDM) panels are available in a 24 port or 48 port, flat, angled or recessed angled configuration.
The panel consists of a rack mounted base unit, rear cable management, labels for port numbering, hardware kit and hook and loop straps. Each panel mounts in a 19-inch (483mm) equipment rack with universal hole spacing. Ordering information is listed below:
Anyag ID | rész sz. | Leírás |
760237040 | CPP-UDDM-SL-1U-24 | Árnyékolatlan diszkrét elosztómodul panel, SL, 1U, 24 port, fekete |
760237041 | CPP-UDDM-SL-2U-48 | Árnyékolatlan diszkrét elosztómodul panel, SL, 2U, 48 port, fekete |
760237042 | CPPA-UDDM-SL-1U-24 | Árnyékolatlan, ferde, diszkrét elosztómodul panel, SL, 1U, 24 port, fekete |
760237043 | CPPA-UDDM-SL-2U-48 | Árnyékolatlan, ferde, diszkrét elosztómodul panel, SL, 2U, 48 port, fekete |
760237044 | CPPR-UDDM-SL-1U-24 | Árnyékolatlan, süllyesztett, ferde, diszkrét elosztómodul-panel, SL, 1U, 24 port, fekete |
760237045 | CPPR-UDDM-SL-2U-48 | Árnyékolatlan, süllyesztett, ferde, diszkrét elosztómodul-panel, SL, 2U, 48 port, fekete |
760237052 | CPP-UDDM-KJ-1U-24 | Árnyékolatlan diszkrét elosztó modulpanel, Keystone, 1U, 24 port, fekete |
760241547 | CPP-UDDM-KJ-2U-48 | Árnyékolatlan diszkrét elosztó modulpanel, Keystone, 2U, 48 port, fekete |
760250319 | CPPA-UDDM-KJ-1U-24-WH | Unshielded Angled Discrete Distribution Module Panel, Keystone, 1U, 24 port, White |
760250320 | CPPA-UDDM-KJ-2U-48-WH | Unshielded Angled Discrete Distribution Module Panel, Keystone, 2U, 48 port, White |
760253047 | CPPA-UDDM-KJ-1U-24 | Árnyékolatlan, ferde, diszkrét elosztómodul panel, Keystone, 1U, 24 port, fekete |
760253048 | CPPA-UDDM-KJ-2U-48 | Árnyékolatlan, ferde, diszkrét elosztómodul panel, Keystone, 2U, 48 port, fekete |
Jegyzet: sampA termék képei alább láthatók referenciaként.
Szükséges eszközök
- Phillips fejű csavarhúzó.
- Flat blade screwdriver, max 2.9mm dia.
Alkatrészlista
Ellenőrizze az alkatrészeket az alábbi alkatrészlista alapján:
24 portos Lapos panel |
48 portos Lapos panel |
Mennyiség
24 portos 48-Port Ang Panel Ang panel |
24 portos R-Ang Panel |
48-Kikötő R-Ang Panel |
Leírás | |
1 | ― | ― | ― | ― | ― | 24 portos lapos panel |
― | 1 | ― | ― | ― | ― | 48 portos lapos panel |
― | ― | 1 | ― | ― | ― | 24 portos ferde panel |
― | ― | ― | 1 | ― | ― | 48 portos ferde panel |
― | ― | ― | ― | 1 | ― | 24 portos süllyesztett szögletes panel |
― | ― | ― | ― | ― | 1 | 48 portos süllyesztett szögletes panel |
1 | 1 | 1 | 1 | 1 | 1 | P12-24 x ½” mounting screw kit |
1 | 2 | 1 | 2 | 1 | 2 | Címketartó készlet |
1 | 2 | 1 | 2 | 1 | 2 | Rear cable management |
1 | 2 | 1 | 2 | 1 | 2 | Hook-and-loop straps kit |
FIGYELMEZTETÉS – Fontos biztonsági utasítások
A termék használata során a következő alapvető biztonsági óvintézkedéseket kell betartani a tűz, áramütés és személyi sérülések kockázatának csökkentése érdekében:
- Soha ne telepítse a kommunikációs vezetékeket nedves helyre, hacsak nem nedves helyekre tervezték.
- Soha ne telepítse ezt a terméket villámlás közben. Fennáll az áramütés veszélye.
- Soha ne érintse meg a szigeteletlen kommunikációs vezetékeket vagy terminálokat, kivéve, ha a kommunikációs áramkört a hálózati interfészen leválasztották.
- Vigyázat: A berendezéshez csatlakoztatott összes vezetéknek meg kell felelnie a vonatkozó helyi és nemzeti építési előírásoknak és a kommunikációs kábelekre vonatkozó hálózati vezetékezési szabványoknak.
Installation of Panel
1. lépés – Szerelje fel a panelt az állványra
Step 2 – Assemble Rear Cable Management and Other Accessories
Attach rear cable management as shown and insert four hook-and-loop straps to the rear cable management.
Step 3 – Populate Panel with Jacks (Jacks ordered separately)
24 portos panel
- Connect cables to jacks per instructions provided with the individual jacks.
- Populate panel with jacks and route cabling as shown.
Jegyzet: Secure cables using the hook-and-loop straps provided.
4. lépés – Információs címkék csatolása
- Enter information on the white information labels provided in label holder kits. Snap holders into panel modules and insert labels into label holders as shown in the above image.
- To print a designation label
- Menj ide http://www.commscope.com/Resources/Labeling-Templates and scroll down to “Copper Panels” and select the proper label template. Or go to https://www.commscope.com/ and search individual part number (material ID).
- Select the part number and scroll down to the “documentation and downloads” section. In the template section, select the required label size.
Jegyzet: Címkézés webaz oldalon két lehetőség van a címkék nyomtatására; levél méretű és A4-es méretű.
- Insert a small, 2.9mm dia. max flat-blade screwdriver into the slot above the jack and rotate to release the latch.
- Remove jack from rear of panel.
- Jegyzet – rear cable management may need to be removed to enable access to the release slot on some jack positions.
Védjegyek
Minden ® vagy ™ védjegy a CommScope, Inc. bejegyzett védjegye vagy védjegye. Ez a dokumentum csak tervezési célokat szolgál, és nem célja a CommScope termékekre vagy szolgáltatásokra vonatkozó specifikációk vagy garanciák módosítása vagy kiegészítése. A CommScope elkötelezte magát az üzleti integritás és a környezeti fenntarthatóság legmagasabb követelményei mellett, mivel a CommScope számos létesítménye világszerte tanúsított a nemzetközi szabványok szerint, beleértve az ISO 9001, TL 9000 és ISO 14001 szabványokat.
A CommScope elkötelezettségével kapcsolatos további információk a következő címen találhatók: https://www.commscope.com/corporate-responsibility-and-sustainability/.
Elérhetőségi adatok
Látogass el hozzánk webwebhelyen, vagy további információért forduljon a CommScope helyi képviselőjéhez.
Technikai segítségért, ügyfélszolgálatért vagy hiányzó/sérült alkatrészek bejelentéséhez keressen fel minket a következő címen: http://www.commscope.com/SupportCenter Or Contact PartnerPRO Network Partner https://www.commscope.com/partners/
Ez a termék egy vagy több egyesült államokbeli szabadalom vagy azok külföldi megfelelője által védett lehet. A szabadalmakhoz lásd www.cs-pat.com
Biztonsági óvintézkedések
When using this product, follow these safety precautions to reduce the risk of fire, electric shock, and injury:
- Never install communications wiring in wet locations unless designed for wet areas.
- Avoid installation during lightning storms due to the risk of electric shock.
- Avoid touching uninsulated communication wiring or terminals unless disconnected at the network interface.
- Ensure all wiring connected to the equipment meets local and national building codes and network wiring standards.
GYIK
Alkalmasak ezek a panelek kültéri használatra?
No, it is recommended to avoid installing communications wiring in wet locations unless specifically designed for such environments.
Milyen eszközök szükségesek a telepítéshez?
You will need a Phillips head screwdriver and a flat blade screwdriver with a maximum diameter of 2.9mm.
Dokumentumok / Források
![]() |
COMMSCOPE CPP-UDDM-SL-1U-24 árnyékolatlan diszkrét elosztómodul [pdfTelepítési útmutató CPP-UDDM-SL-1U-24, CPP-UDDM-SL-2U-48, CPPA-UDDM-SL-1U-24, CPPA-UDDM-SL-2U-48, CPPR-UDDM-SL-1U-24, CPPR-UDDM-SL-2U-48, CPP-UDDM-SL-1U-24 árnyékolatlan diszkrét elosztómodul, CPP-UDDM-SL-1U-24, árnyékolatlan diszkrét elosztómodul, diszkrét elosztómodul, elosztómodul |