CHC WB10 UFH Thermostat Programmer

Műszaki adatok
- Termék neve: WB10 Wiring Center
- Kompatibilis: Radiator or HWC Control, UFH Thermostat Programmer
- Jellemzők: Zone 10 Radiator Thermostat/Programmer, Volts Free Appliance Switching, UFH Motorised Valve
A termék használati útmutatója
Telepítés
- A telepítés előtt győződjön meg arról, hogy az áramellátás ki van kapcsolva.
- Connect the wiring center to the appropriate devices as per the manual.
- If using UFH Motorised Valve or Additional Pump, follow specific instructions for installation.
Programozás
- Set up Zone 10 Radiator Thermostat/Programmer and UFH Thermostat Programmer as needed.
- Configure settings for controlling radiators, UFH pump, and boiler based on your requirements.
Művelet
- Activate Zone 10 control for the Radiator Zone or DHW Cylinder based on your preference.
- In Rad Mode, Zone 10 will not activate the UFH pump, UFH motor Valve, or Boiler.
- Use the end switch of a motorised valve or relay to signal the heat source as required.
WB10 – 10 ZONE WIRING CENTRE
- The WB10 is a 10 Zone wiring centre for use with 230V thermostats; the outline dimension is 32 cm * 11 cm * 6.5 cm.
- The WB10 can be used to control any actuator or valve that requires a 230V AC signal to open.
- For mid-position valves and those requiring a closing signal, a changeover relay is required. At the same time, the WB10 offers the ability to operate a boiler or other heat source through a voltage-mentes kimenet.
- Additional outputs designed for use with under-floor heating systems are also included as standard.
- These are the pump and valve outputs, which would normally operate a manifold pump or a manifold valve.
The pump delay time is 3 minutes:
- Zone 10 can be used as an isolated radiator zone by using the UFH/RAD switch.
- If the switch is set to RAD, when zone 10 calls for heat, this will provide an output to a radiator zone valve and the boiler, but WILL NOT enable the underfloor heating pump/valve output.
- If the switch is set to UFH, when Zone 10 calls for heat, this will act as an under-floor heating zone by enabling the actuator, boiler, and pump/valve outputs. Any output that is not needed can be ignored.
KAPCSOLATOK
- Hálózati ellátás
- Power supply into the WB10, which should be fused at 5 amps, these connections are;
- L = Live or phase 230V AC 50/60 Hz
- E = Föld
- N = Semleges
- Fűtés engedélyezése
- This is the main call for heat for the system. There are 3 connections.
- LS = Élő ellátás
- E = Föld
- LR = Élő visszatérés
- Electrically, this is a voltage-free switch; whatever supply is placed on the LS connection is fed to the LR connection when there is a call for heat.
- Idő Óra
- L = Live supply
- E = Föld
- N = Neutral supply
- = Switch live input from the time clock, this triggers the time clock 1 terminal on the thermostat connections.
- = Switch live input from the time clock, this triggers the time clock 2 terminal on the thermostat connections.
- Zónák 1…10 (bemenetek)
- Zone inputs are clearly marked at the top of the circuit board.
- L = Live supply to the thermostat
- E = Föld
- N = Neutral supply to the thermostat
- S/L = 230 V switch live from the thermostat, which activates the corresponding zone output.
Zónák 1…10 (kimenetek)
- Zones’ outputs are clearly marked
- L = live out to actuator or valve
- N = neutral to actuator or valve
- There are two connections live (L) and neutral (N), both terminals marked L are the same, and both terminals marked N are the same.
- Each zone output corresponds to the thermostat wired in at the top of the PCB.
UFH szivattyú
- Used for an underfloor heating manifold pump, connections are;
- L = Élőben
- E = Föld
- N = Semleges
- When an under-floor heating zone sends a call for heat to the WB10, the live & neutral output will supply 230V to the manifold pump.
- The delay time is 3 minutes.
- It is recommended that this be fed through a high-limit switch placed on the heating manifold to protect against mechanical failure of the manifold temperature control.
UFH szelep
- Used for an underfloor heating manifold valve.
- Connections are clearly marked.
- To enable Pump delay, or and Gr must be shortened.
- Or = Narancs
- Gr = Grey
- L = Élő
- E = Föld
- N = Semleges
- When an under-floor heating zone sends a call for heat to the WB10, the live & neutral output will supply 230V to the manifold valve.
- A szelep segédvezetékei, általában szürke és narancssárga, a Gr & Or kapcsokhoz vannak kötve.
Biztosítékok
- Biztosíték 1. 5 amp, 20 mm anti-surge fuse, this fuse supplies power to all 230V outputs from the board, it protects the zone, pump/valve outputs.
Bekötési központ
WB10 Wiring center with optional radiator or HWC control

GYIK
What should be done if not using a motor valve with the UFH system?
The factory link between Or & Gr must remain in place to ensure proper functioning of the system.
How can I control additional zones with the product?
Optional Zone 10 Radiator Thermostat/Programmer can be used to control additional zones such as radiators or DHW cylinders.
Dokumentumok / Források
![]() |
CHC WB10 UFH Thermostat Programmer [pdfUtasítások 101Z, WB10, Zone 10, WB10 UFH Thermostat Programmer, WB10, UFH Thermostat Programmer, Thermostat Programmer, Programmer |