CHC-LOGO

CHC WB10 UFH Thermostat Programmer

CHC-WB10-UFH-Thermostat-Programmer-PRODUCT

Műszaki adatok

  • Termék neve: WB10 Wiring Center
  • Kompatibilis: Radiator or HWC Control, UFH Thermostat Programmer
  • Jellemzők: Zone 10 Radiator Thermostat/Programmer, Volts Free Appliance Switching, UFH Motorised Valve

A termék használati útmutatója

Telepítés

  1. A telepítés előtt győződjön meg arról, hogy az áramellátás ki van kapcsolva.
  2. Connect the wiring center to the appropriate devices as per the manual.
  3. If using UFH Motorised Valve or Additional Pump, follow specific instructions for installation.

Programozás

  1. Set up Zone 10 Radiator Thermostat/Programmer and UFH Thermostat Programmer as needed.
  2. Configure settings for controlling radiators, UFH pump, and boiler based on your requirements.

Művelet

  1. Activate Zone 10 control for the Radiator Zone or DHW Cylinder based on your preference.
  2. In Rad Mode, Zone 10 will not activate the UFH pump, UFH motor Valve, or Boiler.
  3. Use the end switch of a motorised valve or relay to signal the heat source as required.

WB10 – 10 ZONE WIRING CENTRE

  • The WB10 is a 10 Zone wiring centre for use with 230V thermostats; the outline dimension is 32 cm * 11 cm * 6.5 cm.
  • The WB10 can be used to control any actuator or valve that requires a 230V AC signal to open.
  • For mid-position valves and those requiring a closing signal, a changeover relay is required. At the same time, the WB10 offers the ability to operate a boiler or other heat source through a voltage-mentes kimenet.
  • Additional outputs designed for use with under-floor heating systems are also included as standard.
  • These are the pump and valve outputs, which would normally operate a manifold pump or a manifold valve.

The pump delay time is 3 minutes:

  • Zone 10 can be used as an isolated radiator zone by using the UFH/RAD switch.
  • If the switch is set to RAD, when zone 10 calls for heat, this will provide an output to a radiator zone valve and the boiler, but WILL NOT enable the underfloor heating pump/valve output.
  • If the switch is set to UFH, when Zone 10 calls for heat, this will act as an under-floor heating zone by enabling the actuator, boiler, and pump/valve outputs. Any output that is not needed can be ignored.

KAPCSOLATOK

  • Hálózati ellátás
    • Power supply into the WB10, which should be fused at 5 amps, these connections are;
    • L = Live or phase 230V AC 50/60 Hz
    • E = Föld
    • N = Semleges
  • Fűtés engedélyezése
    • This is the main call for heat for the system. There are 3 connections.
    • LS = Élő ellátás
    • E = Föld
    • LR = Élő visszatérés
  • Electrically, this is a voltage-free switch; whatever supply is placed on the LS connection is fed to the LR connection when there is a call for heat.
    • Idő Óra
    • L = Live supply
    • E = Föld
    • N = Neutral supply
      1. = Switch live input from the time clock, this triggers the time clock 1 terminal on the thermostat connections.
      2. = Switch live input from the time clock, this triggers the time clock 2 terminal on the thermostat connections.
  • Zónák 1…10 (bemenetek)
    • Zone inputs are clearly marked at the top of the circuit board.
    • L = Live supply to the thermostat
    • E = Föld
    • N = Neutral supply to the thermostat
    • S/L = 230 V switch live from the thermostat, which activates the corresponding zone output.

Zónák 1…10 (kimenetek)

  • Zones’ outputs are clearly marked
    • L = live out to actuator or valve
    • N = neutral to actuator or valve
  • There are two connections live (L) and neutral (N), both terminals marked L are the same, and both terminals marked N are the same.
  • Each zone output corresponds to the thermostat wired in at the top of the PCB.

UFH szivattyú

  • Used for an underfloor heating manifold pump, connections are;
    • L = Élőben
    • E = Föld
    • N = Semleges
  • When an under-floor heating zone sends a call for heat to the WB10, the live & neutral output will supply 230V to the manifold pump.
  • The delay time is 3 minutes.
  • It is recommended that this be fed through a high-limit switch placed on the heating manifold to protect against mechanical failure of the manifold temperature control.

UFH szelep

  • Used for an underfloor heating manifold valve.
  • Connections are clearly marked.
  • To enable Pump delay, or and Gr must be shortened.
    • Or = Narancs
    • Gr = Grey
    • L = Élő
    • E = Föld
    • N = Semleges
  • When an under-floor heating zone sends a call for heat to the WB10, the live & neutral output will supply 230V to the manifold valve.
  • A szelep segédvezetékei, általában szürke és narancssárga, a Gr & Or kapcsokhoz vannak kötve.

Biztosítékok

  • Biztosíték 1. 5 amp, 20 mm anti-surge fuse, this fuse supplies power to all 230V outputs from the board, it protects the zone, pump/valve outputs.

Bekötési központ

WB10 Wiring center with optional radiator or HWC controlCHC-WB10-UFH-Thermostat-Programmer-FIG-1 CHC-WB10-UFH-Thermostat-Programmer-FIG-2

WWW.THERM.CO.UK

GYIK

What should be done if not using a motor valve with the UFH system?

The factory link between Or & Gr must remain in place to ensure proper functioning of the system.

How can I control additional zones with the product?

Optional Zone 10 Radiator Thermostat/Programmer can be used to control additional zones such as radiators or DHW cylinders.

Dokumentumok / Források

CHC WB10 UFH Thermostat Programmer [pdfUtasítások
101Z, WB10, Zone 10, WB10 UFH Thermostat Programmer, WB10, UFH Thermostat Programmer, Thermostat Programmer, Programmer

Hivatkozások

Hagyj megjegyzést

E-mail címét nem tesszük közzé. A kötelező mezők meg vannak jelölve *